Light Curtain Power Failure & Forced Power-on Protection

OTCP2 controller identifies safety travel signals and offers two selectable modes, A and B. In mode A, the light curtain provides full-range protection; in mode B, the cam switch signal blocks the light curtain signal, eliminating protection during the return stroke. The OTCP2 controller has no function switch, providing both power-off protection and forced power-on protection, thus avoiding safety hazards caused by not using photoelectric protection devices.

Environmental Characteristics

Ambient Temperature: Operating -10℃~55℃ (no frost or condensation)
Storage: -40℃~70℃
Ambient Humidity: Operating 35%RH~85%RH
Storage 35%RH~95%RH
Protection Rating: IP54
Dimensions: 216×82×215mm
Electrical Characteristics:
Power Supply: AC100V~230V±15%, 50/60Hz; DC24V±10% (cascaded)
Power Consumption: ≤15W, ≤30W with cascaded light curtain
Main Control Output (OSSD): Two sets of normally open safety relay contacts in series
Emergency Stop Button Auxiliary Output: Emergency stop button auxiliary output, safety relay contact output, two normally open signals
Safety Door Auxiliary Output: Safety door auxiliary output, safety relay contact output, one normally open signal
Safety Light Curtain Auxiliary Output: Safety relay contact output, two output signals, one normally open and one normally closed
Output Contact Capacity: 5A AC250V/DC30V (Resistive Load)
Response Time ≤20ms
Insulation Resistance >100MΩ
Dielectric Strength AC1500V, 60S No Breakdown or Flashover
Relay Life ≥1 million cycles (Electrical Life)
Relay Mechanical Life ≥10 million cycles (Information from Safety Relay Manual)